beautypg.com

12 2b 2a – Comelit MT 8171IGK User Manual

Page 13

background image

13

13

EN

1

2

3

4

1

2

3

4

5

6

3

4

5

CV

4 CV

3

DIP

140-145 cm

115-125 cm

CV

4 CV

3

DIP

1

2

2B

2A

14,4cm

8,1cm 1,4cm

1,4cm

10,3cm

10,1cm

Internal units

Art. 5801

Technical characteristics - Monochrome monitor Art. 5801
1
Monitor handset (lift the handset to start communication).
2 3-position ringtone selector:
æ

,EFTæPOSITIONæ#ALLæTONEæATæMAXIMUMæVOLUME

Central position: Call tone at medium volume

Right position: Minimum ringtone volume.

3 Brightness control knob (turn anticlockwise to increase brightness).
4

æ væ"LACKæANDæWHITEæSCREEN

Description of buttons:
A Key button.
P1 Button available as standard for generic actuator, can be used for

various services (C.NO. contact 1 A max.) depending on system
requirements; removing CV3 and CV4 as specified in variant GK/PI on
page 69.

P2 Button available as standard for Automatic switch-on/Video request.

Art. 5814K

1 JP2 Jumper for programming user addresses.
2 Bracket-Monitor connector.
3 JP1 Jumper for programming the bracket as Main (M) or Secondary

(S) (see page 16).

4 CV3

CV4 Jumpers for freeing Button 1 (C. NO. contact 24 V- 100 mA

max.).

5 Terminal block for system connection:

0V 20V Terminals for connection to Art. 1207 or 1212/B.

L L Bus line connection terminals.

CFP CFP Floor door call input.

P1 C1 Contacts for Button 1 used for various purposes.

To have a C.NO. contact (24 V-100 mA max.), remove jumpers CV3
and CV4.

+S -S Terminals for call repetition device.

6 CV5 Jumper for video closure.

Installing Art. 5801 as a flush- or wall-mounted device