beautypg.com

General maintenance, Caution – Autoquip TRUCK LEVELER - SHALLOW PIT MOUNT User Manual

Page 33

background image

33

Power Unit

115 Volts

208 Volts

230 Volts

460 Volts

Standard Three Phase

N/A

16 AMPS

15.2 AMPS

7.6 AMPS

Standard Single Phase

58 AMPS

N/A

24.5 AMPS

N/A

NOTE: All amperage draws shown are full-load amperages.

A. DISASSEMBLY – VERTICAL POWER UNIT

1. Remove the down solenoid by disconnecting the wiring and removing the two

screws holding the solenoid and cover to the Deltatrol.

CAUTION!

Precaution should be taken to prevent the introduction of contaminates
such as dirt or other foreign material into the system through open fittings,
pipes, or disassembled components. Contamination will ruin the hydraulic
system.

2. Remove the four screws holding the reservoir lid in place. One screw is through the

Deltatrol. Lift the reservoir lid off of the reservoir, taking note of the orientation; keep
the gasket so that it may be used during reassembly.

3. Disconnect the hoses and down restrictor pipe from the Deltatrol.

4. Remove the Deltatrol and gasket by removing the one screw. Take note of the

orientation of the pump and plumbing for reassembly.

5. Remove the hose and suction pipe, with filter, from the pump. Take note of the

orientation of the pump and plumbing for reassembly.

6. Disconnect the control box and wiring from the motor. Note the connections for

reassembly.

7. Place the motor on end and remove the four screws from the reservoir lid that hold

the pump and motor on.

8. Remove the reservoir lid and gasket from the pump and separate the pump,

coupling, and motor. Take note of the orientation of all parts for reassembly.

GENERAL MAINTENANCE

This manual is related to the following products: