PROBLEM
POSSIBLE CAUSE AND SOLUTION
Lift will not lower.
•
The down solenoid may be malfunctioning.
•
The structural members may be in a bind.
•
The piping is obstructed or broken.
•
The return filter may be clogged.
•
Should the above steps not correct the problem,
contact Autoquip to obtain instruction for further
action.
Lift raises slowly.
•
The structural members of the lift may be binding.
•
The piping is obstructed or broken. Where pipe is
used, check for obstruction in the line.
•
The hydraulic line or hose may be leaking.
•
The oil viscosity is not suited for the environmental
conditions. Refer to “Routine Maintenance” section
for oil requirements.
•
Check the oil level in the reservoir.
•
The motor voltage/wiring may be incorrect.
•
The suction screen may be clogged. Remove and
clean the screen. Drain and replace the oil.
•
The suction line may be leaking air due to a loose
fitting. Tighten as needed.
•
The breather holes in the reservoir fill cap may be
clogged. Remove and clean.
•
The power unit pump may be defective.
Lift lowers slowly.
•
The structural members of the lift are binding.
•
The tubing or hose is obstructed or broken. Where
pipe is used, check for obstruction in the line.
•
The oil viscosity is not suited for the environmental
conditions. Refer to “Routine Maintenance” section
for oil requirements.