PROBLEM

POSSIBLE CAUSE AND SOLUTION

Lift will not lower.

The down solenoid may be malfunctioning.

The structural members may be in a bind.

The piping is obstructed or broken.

The return filter may be clogged.

Should the above steps not correct the problem,

contact Autoquip to obtain instruction for further
action.

Lift raises slowly.

The structural members of the lift may be binding.

The piping is obstructed or broken. Where pipe is

used, check for obstruction in the line.

The hydraulic line or hose may be leaking.

The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil requirements.

Check the oil level in the reservoir.

The motor voltage/wiring may be incorrect.

The suction screen may be clogged. Remove and

clean the screen. Drain and replace the oil.

The suction line may be leaking air due to a loose

fitting. Tighten as needed.

The breather holes in the reservoir fill cap may be

clogged. Remove and clean.

The power unit pump may be defective.

Lift lowers slowly.

The structural members of the lift are binding.

The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil requirements.