beautypg.com

General maintenance, Danger – Autoquip SERIES 35 LOW PROFILE User Manual

Page 34

background image



GENERAL MAINTENANCE

VELOCITY FUSE REPLACEMENT

DANGER

!

Do not attempt to remove the velocity fuse until the lift is
securely supported with the maintenance locking devices and all
hydraulic pressure has been removed from the lifting cylinders
and hydraulic hoses. Failure to follow these instructions could
result in personal injury or death!


Never attempt to take a velocity fuse apart and repair it. These are precision devices
that are factory assembled under exacting conditions. Velocity fuses should always be
replaced.

1. The arrow on the exterior surface of the velocity fuse shows the direction of the

restriction to the oil flow. The arrow should always point away from the cylinder.


2. Do not use Teflon tape on the threaded connections of a velocity fuse.

Tape fragments can cause malfunctioning of the fuse.


3. Check all fitting connections for hydraulic leaks and tighten as necessary.


HOSE ORIENTATION


To prevent damage to the cylinder hose and possible failure of lift, it is necessary to
establish a correct hose shape and pattern of movement as follows:

1. Raise the lift to its full height and block securely. See “Lift Blocking Instructions”.

2. Install one end of the new hose to the cylinder elbow fitting.

3. Since the hose is fixed at both ends, it is possible to put a twist in the hose that

will allow it to describe the same pattern each time the lift is operated. This twist
will allow the hose to travel about half way between the cylinder on the right side
and the inner leg on the right side.

4. Lower the lift carefully and check to see that the hose is free and clear of the

cylinder and the inner leg assembly. If not, twist the hose in the direction
necessary to clear it of any obstruction and then lock the swivel fitting securely.

34