General maintenance, Warning – Autoquip SERIES 35 LOW PROFILE User Manual
Page 32

 
 
GENERAL MAINTENANCE
WARNING
!
Before maintaining the lift, read & follow the recommended 
safety practices in the Safety Practices section. Failure to follow 
these safety practices could result in death or serious injury. 
 
CYLINDER REMOVAL AND REPACKING 
1. Raise the lift to its full height and block securely. See “Lift Blocking Instructions”.
2. Cut off the electricity to the power unit (lock out-tag out). 
 
3. Disconnect the cylinder hose at the power unit end and insert it into the oil-fill
hole of reservoir.
4. Loosen the setscrew or hex bolt in the cylinder upper leg clevis (otherwise known
as the Trunnion clevis).
 
5. Remove the cylinder pin from the upper leg clevis. 
 
6. Lift the cylinder out of the leg assembly. 
 
7. Push the piston rod into the cylinder to eject as much oil as possible into a 
container.
 
8. Insert a Spanner wrench and turn the upper bearing assembly clockwise until the 
tip of the retainer appears in the slot. Place a small screwdriver under the 
retainer and turn it until the retainer is completely removed. 
 
9. Be sure the hose port is open to allow air into the cylinder. Pull the piston rod out 
to remove the upper bearing.
 
10. After all of the internal components have been removed, use a bright light to 
inspect the inner walls of the barrel. Use a cylinder hone to remove any apparent 
nicks or scratches. Clean and flush the barrel after honing. 
 
11. Remove the piston head nut from the rod. The upper clevis and pin may be used 
to prevent rotation of the rod while loosening. Remove the old piston.
 
12. Inspect the groove for nicks or scratches that could affect the seal or barrel walls; 
remove as necessary.
 
13. Install the new piston, seals, and rod wiper. 
32