Troubleshooting analysis – Autoquip PLD DOCK LIFT User Manual

Page 37

background image

37

Lift raises slowly.

The structural members of the lift may be binding.

The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

The hydraulic line or hose may be leaking.

The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

Check the oil level in the reservoir.

The motor voltage/wiring may be incorrect.

The suction screen may be clogged. Remove and

clean the screen. Drain and replace the oil.

The suction line may be leaking air due to a loose

fitting. Tighten as needed.

The breather holes in the reservoir fill plug may be

clogged. Remove and clean.

The power unit pump may be defective.

Lift lowers slowly.

The structural members of the lift are binding.

The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

The return filter may be clogged due to dirt or

damage.

PROBLEM

POSSIBLE CAUSE AND SOLUTION

TROUBLESHOOTING ANALYSIS