General maintenance – Autoquip PLD DOCK LIFT User Manual
Page 23
23
2. The following should be referenced in connecting the standard heavy-duty motors to
power sources. Remember that heavy wire must be used all the way to the power
source.
Power Unit
115 Volts
208 Volts
230 Volts
460 Volts
Standard Three Phase
N/A
16 amps
15.2 amps
7.6 amps
Standard Single Phase
58 amps
N/A
24.5 amps
N/A
NOTE: All amperage draws shown are full-load amperages.
MOTOR CONNECTION DIAGRAMS
AIR BLEEDING PROCEDURE
1. Press and hold the “UP” button, release when the unit has raised halfway up.
2. Crack the bleed screw on top of the cylinder until clear oil (no bubbles) comes from
the cracked bleed screw.
3. Tighten the screw; make sure no oil comes from the screw when it is tightened.
4. Clean up any spilled oil. Used oil should be discarded as it may contain flushed
contaminates from the line.
NOTE: A small amount of air may remain in the cylinder, but it will be flushed back to
the reservoir after a few operations of the system.
GENERAL MAINTENANCE