CC

AS

MOTOR STARTER

CONTACTOR

COIL

O.L. RELAY

CONTACT

L1

L2

FUSED DISCONNECT

(BY OTHERS)

CONTACTS

O

.L.

MOTOR STARTER

L1

L2

T1

3

L1

L2

TRANSFORMER

(13)

(14)

6

3

6

AUDIBLE SIGNAL

(WHEN USED)

3

3

3

3

(XF)

(X1)

(X2)

"UP" LIMIT SWITCH

(WHEN USED)

5

4

AUX.

CONTACT

AUX.

CONTACT

DN. SOL.

(BY AUTOQUIP)

7

ORG.

BLU.

2

2

2

JUMPER

*BLK.

*

WHT.

*GRN.

*RED.

PUSHBUTTON

UP

DN

PRIMARY FUSE(S)

SECONDARY FUSE

NOTES:

1. "UP" LIMIT SWITCH ( OPTIONAL) WHEN USED, REMOVE JUMPER BETWEEEN #4 AND #5.

2. "R" = RED FLASHING LIGHT (OPTIONAL).

3. "AS" = AUDIBLE SIGNAL (OPTIONAL).

4. SEE ASSEMBLY AND/OR SPEC. SHEET FOR SPECIFIC VOLTAGES, OR CONTROLS

SUPPLIED AND CONFIGURATION.

5. PUSHBUTTON SHOWN AS TYPICAL PILOT DEVICE.

6. TRANSFORMER PRIMARY CONNECTION DIAGRAMS ARE LOCATED ON INSIDE

FRONT COVER OR ON DEVICE.

* COLOR CODE OF STANDARD PENDENT PUSHBUTTON WHEN SUPPLIED.

( ) INDICATES ACTUAL TERMINAL

CONNECTION No. ON DEVICE

6

6

R

(A1)

(A2)

(95)

(96)

(52)

(51)

+

-

FLASHING RED LIGHT

(WHEN USED)

(GRN.)

(BLK.)

(WHT.)

FIELD WIRING TYP.

(BY OTHERS)

L2

L1

L3

T2

T3

Figure 11 Electrical Schematic; 230V/1PH (PLD-50)