beautypg.com

General maintenance – Autoquip COIL TRANSFER CARS User Manual

Page 23

background image

23

15. Restore the oil level.

16. Loosen the bleeder plug at the top end of the ram casing and operate the pump to

remove trapped air from the ram. When clear oil appears, tighten the plug and
raise the lift slightly to remove the maintenance locks.

17. Lower the lift completely and hold the “DOWN” button for 30-40 seconds to allow

air in the lines to bleed back into the tank.

18. Cycle the lift 10 – 15 times.

19. Check the oil level.

20. Clean the oil fill breather cap.

21. Clean up any debris and/or spilled oil from the area.

NOTE: Depending on experience, the job should take 1 – 2 hours.

PIPE THREAD SEALANT

Loctite PST #567 pipe thread sealant or equivalent is recommended. Do not use
Teflon tape.
Tape fragments can cause malfunctioning of the hydraulic system.

GENERAL MAINTENANCE