Troubleshooting analysis – Autoquip DOUBLE PANTOGRAPH LIFT User Manual

Page 70

background image

70


PROBLEM POSSIBLE

CAUSE AND SOLUTION


Lift Raises Slowly.

• The structural members of the lift may be binding.

• Check for pinched hose or tubing. Where pipe is

used, check for obstruction in the line.

• The hydraulic line or hose may be leaking.

• The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

• Check the oil level in the reservoir.

• The motor voltage/wiring may be incorrect.

• The suction screen may be clogged. Remove and

clean the screen. Drain and replace the oil.

• The suction line may be leaking air due to a loose

fitting. Tighten as needed.

• The breather holes in the reservoir fill plug may be

clogged. Remove and clean.

• The power unit pump may be defective.


Lift lowers slowly.

• The structural members of the lift are binding.

• Check for pinched hose or tubing. Where pipe is

used, check for obstruction in the line.

• The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

• The return filter may be clogged due to dirt or

damage. (Vertical PU)


• The connecting hose on a Remote power unit

maybe too small. See "Lift & Hose Installation" in
Installation Instructions

TROUBLESHOOTING ANALYSIS