Troubleshooting analysis – Autoquip DOUBLE PANTOGRAPH LIFT User Manual
Page 70
70
PROBLEM POSSIBLE
CAUSE AND SOLUTION
Lift Raises Slowly.
• The structural members of the lift may be binding.
• Check for pinched hose or tubing. Where pipe is
used, check for obstruction in the line.
• The hydraulic line or hose may be leaking.
• The oil viscosity is not suited for the environmental
conditions. Refer to “Routine Maintenance” section
for oil recommendations.
• Check the oil level in the reservoir.
• The motor voltage/wiring may be incorrect.
• The suction screen may be clogged. Remove and
clean the screen. Drain and replace the oil.
• The suction line may be leaking air due to a loose
fitting. Tighten as needed.
• The breather holes in the reservoir fill plug may be
clogged. Remove and clean.
• The power unit pump may be defective.
Lift lowers slowly.
• The structural members of the lift are binding.
• Check for pinched hose or tubing. Where pipe is
used, check for obstruction in the line.
• The oil viscosity is not suited for the environmental
conditions. Refer to “Routine Maintenance” section
for oil recommendations.
• The return filter may be clogged due to dirt or
damage. (Vertical PU)
• The connecting hose on a Remote power unit
maybe too small. See "Lift & Hose Installation" in
Installation Instructions
TROUBLESHOOTING ANALYSIS