beautypg.com

Specifications, Caution, Danger – Autoquip DOUBLE PANTOGRAPH LIFT User Manual

Page 16

background image

16




CAUTION!

Lifts should not be overloaded beyond the established capacity as
damage and/or personal injury may result and will void its
warranty.

DANGER!

Do not make modifications to the lift without authorization

from the manufacturer. Autoquip cannot foresee and is

not responsible for injury or damage which results from

the unauthorized modifications or misuse of the lift.


UNBALANCED LOADING


The stabilization provided is basically for balanced loads. If special attachments extend
beyond the length and/or width dimensions of the platform, the end and/or side load
capacity must be reduced (contact an Autoquip Sales representative).

LIFT DUTY

Autoquip standard lift designs as described in the specifications typically include
intermittent duty motors and are designed to “cycle” (one complete “up” and one complete
“down” lift operation) no more frequently than every two minutes – or approximately 60,000
times (cycles) per year. This is considered “normal” duty.

It is the responsibility of the user to notify Autoquip whenever a specific application is likely
to demand “above normal” duty from the lift - in excess of 60,000 cycles per year. Above
normal duty typically requires supplemental design features to enhance the serviceable life
of the lift & to avoid loss of warranty.



PUMP PRESSURE


This lift incorporates a positive displacement pump machined to a high degree of accuracy
and specially adapted to requirements of higher-pressure ranges over that of a standard
pump. Therefore, standard factory models of the same manufacture cannot replace it.

The pump can operate efficiently at intermittent pressures up to 3200 PSI and continuous
duty to 2500 PSI. The safety relief valve in the pump assembly or Deltatrol Valve is
factory-set to stay within the parameters of the pump and lift requirements.

SPECIFICATIONS