beautypg.com

Routine maintenance, Notice – Autoquip DOUBLE PANTOGRAPH LIFT User Manual

Page 38

background image

38



NOTICE!


Use approved fluids only! Use of unauthorized fluids may
cause damage to seals and hosing.

DO NOT USE:


1. Automatic Transmission Fluid (ATF)
2. Hydraulic Jack Oil
3. Hydraulic Fluids
4. Brake Fluids

Standard Factory recommended fluid is SAE 5W30 motor oil. See Oil Recommendations
on previous page.

BLEEDING AIR FROM THE SYSTEM


1. Bleed any air which may have been entrapped in the hydraulic system by raising the lift

to approximately 50% of its full travel, then lower back down completely.


2. Hold the “DOWN” button for approximately 60 seconds.

3. Repeat this process five or six times.

4. Should the above steps not correct the problem, contact Autoquip to obtain instruction

for further action.


5. Clean up any spilled oil. Used oil should be discarded as it may contain flushed

contaminates from the line.

















ROUTINE MAINTENANCE