LIFT & HOSE INSTALLATION – (Reference Figure 3A & 3B)

CAUTION!

Precautions should be taken to prevent the introduction of
contaminates such as dirt or other foreign material into the
hydraulic system through open fittings, pipes or disassembled
components. Contamination will ruin the hydraulic system.

1. Make temporary hose connections with high-pressure hose (see chart below) to

allow the lift to be operated when it is set in the pit.

Hydraulic Piping/Hose Size

Up to 25 feet

1/2" ID

26 feet to 50 feet

3/4” ID

Over 50 feet

1” ID

2. Using 3/4”--10 UNC lifting eyebolts and a chain spreader to place the lift into the pit

as illustrated in Figure 11.

3. Remove the shipping bolt and lifting eye bolts before operating the lift.

Failure to remove the shipping bolts before operating the lift will cause permanent
damage to the lift.
















INSTALLATION INSTRUCTIONS