Setting the Trip Point Outputs:

Step 1: Press the On/Off button once to enter the main setup menu.
Step 2: Press (Z) to cycle through the options until OUTPUT is displayed.
Step 3: Press (S) to access the Output Settings menu.
Step 4: Press (Z) to cycle through the options until T1TYPE (or T2TYPE) is

displayed.

Step 5: Press (S) to access the Trip Type setting.
Step 6: Press (Z) to change the setting to the desired trip type function (see

explanation on previous pages).

Step 7: Press (S) to accept the trip type setting and return to the Output

Settings menu.

Step 8: Press (Z) to cycle through the Output menu options until T1PRES (or

T2PRES) is displayed.

Step 9: Press (S) to enter the Trip Pressure setting.

A 5-digit number will appear

with the first digit flashing.

Step 10: Press (Z) to change the value of the first flashing digit

(options: 0-9 or “-”).

Step 11: Press (S) to accept the value of the flashing digit and advance to the

next digit......repeat steps 10 and 11 until the desired Trip Pressure is
fully entered. After the last digit is accepted by pressing (S), the
display will return to the Output Settings menu.

Step 12:

Press (Z) to cycle through the Output menu options until T1WIN
(or T2WIN) is displayed.

Step 13: Press (S) to enter the Trip Window setting.

A 5-digit number will

appear with the first digit flashing.

Step 14: Press (Z) to change the value of the first flashing digit (options: 0-9).
Step 15: Press (S) to accept the value of the flashing digit and advance to the

next digit......repeat steps 14 and 15 until the desired Trip Window is
fully entered. After the last digit is accepted by pressing (S), the
display will return to the Output Settings menu.

Step 11: To exit the output menu, press (Z) until EXIT is displayed and press (S)

to exit to the main setup menu.