Installation of tek track to an outlet box – Altman Lighting Track Lighting: GLOBALtrac tec 2-circuit / 2-neutral track system User Manual
Page 6

Outlet Box
Outlet Box Canopy Cover
(GES 15)
FEEDS
TEK 11, 12, 14, 34
39, 40, 38
N
L
1
L
2
N
2
1
Ground
STEP 1.
Remove the knock-out hole provided on the back side of the feed connector. Remove feed connector cover.
STEP 2.
Pass the supply, neutral and ground wires through the canopy cover.
STEP 3.
Attach feed connector to track (NOTE: track is polarized and feed connector will only fit one end of track). Pass wires through hole on feed and
mount track to ceiling using toggle bolts or screws.
STEP 4.
ALWAYS CONNECT GROUND WIRE TO GREEN GROUND TERMINAL. Connect live conductors to the appropriate terminal marked "L1", or
"L2". Connect neutral conductors to the appropriate terminal marked "N1" or "N2".
STEP 5.
Replace feed connector cover plate
INSTALLATION OF TEK TRACK TO AN OUTLET BOX