Switching the console on, The protect indicator – Allen&Heath Xone S6 User Manual
Page 28
28
XONE:S6 User Guide
Switching the Console On
The XONE:S6 MPS7 power unit is factory configured to one of
four mains voltage settings, 100V, 120V, 220V or 240V AC. First
check that the setting is correct for your local mains voltage. This
is marked on the power unit rear panel. The setting cannot be
changed by the user. Refer this work to your service agent.
To avoid audible switch-on thumps, turn connected
power amplifiers down or off before switching the console on
or off. Ensure that the IEC mains plug is pressed fully into the
rear panel socket and the DC cable locking rings are screwed
in place before switching on.
To switch the console on
set the power unit POWER ON
switch to its ‘I’ position. There is a delay of a few seconds as the
unit configures itself and the voltage rails stabilise. During this
time you should hear its relays click. After this time the +30, -30
and +6.3V indicators light to show that the power rails are ready.
To switch the console off
set the power unit POWER ON
switch to its ‘0’ position. The PROTECT indicator lights for a few
seconds while the power rails turn off.
The PROTECT indicator
lights when the power unit shuts
down in safe mode. This happens during switch off, and also if a
power rail fault such as short circuit or over-current is detected.
Switch the console off then on again to restore normal operation.
If the fault does not clear then contact your Allen & Heath service
agent for advice.
FUSE
MADE IN ENGLAND BY ALLEN & HEATH Ltd.
~120W MAX
FUSE
MAINS INPUT
S/No
250V
T
T2.5AL
50-60 Hz
240 V AC
POWER RAIL MONITORS
+6.3V
DC POWER OUT
+30V
-30V
PROTECT