4 network connection (rj45), 5 serial com interface (rs232) – ADS-TEC OPC7013/7015/7022 User Manual
Page 29

Industrial PCs OPC7013/7015/7022
© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen
29
6.4
N
ETWORK CONNECTION
(RJ45)
If the drivers required for functioning are installed on the device, the control system may
be integrated in an Ethernet network supporting the 10/100 Mbit standard by using the
Ethernet 10/100BaseT network connector. Specifications of this network topology must be
observed in this case. You can install the drivers required for the network function from
the enclosed service CD, should they not be installed on the device.
PIN NUMBER
SIGNAL NAME
1
TX +
2
TX -
3
RX +
4
NC
5
NC
6
RX -
7
NC
8
NC
Pos : 30 /D atent ec hni k/Schnitts tell en/Seriell e Schnitts tell e C OM RS232/Serielle Sc hnitts tell e C OM (RS232) f ür OPC / I PC / C PC / PLC / OTC / ITC / VMT / M SA- Serie @ 1\ mod_1249303286408_6. doc @ 6104 @
6.5
S
ERIAL
COM
INTERFACE
(RS232)
The serial interface is also used for digital data transmission. The RS232 interface can be
connected by using a commercially available 9-pin SUB-D cable.
PIN NUMBER
SIGNAL NAME
1
DCD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Note:
This interface is not electrically isolated.