Personality ranges/defaults -7 – JLG M400 Service Manual Service Manual User Manual
Page 187
SECTION 6 - JLG CONTROL SYSTEM
3121827
– JLG Lift –
6-7
Table 6-1. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS
DRIVE
ACCELeration
0.5s to 5.0s
1.0
DECELeration
0.1s to 2.0s
0.5
MINimum speed
0 to 25%
3
MAXimum speed
0 to 100%
100
ELEVATED MAXimum speed
0 to 25%
20
CREEP MAXimum speed
0 to 45%
30
POSITRAC time
0 to 60s
10
POSITRAC current
50-250 A
170A
LOWER LIFT
ACCELeration
0.5 to 5.0s
1.0
DECELeration
0.0 to 3.0s
0.5
MINimum UP speed
0 to 30%
19
MAXimum UP speed
0 to 100%
95
MINimum DOWN speed
0 to 20%
7
MAXimum DOWN speed
0 to 100%
47
UPPER LIFT
ACCELeration
0.5 to 5.0
2.0
DECELeration
0.1 to 3.0
1.0
MlNimum UP speed
0 to 20
9
MAXimum UP speed
0 to 100
67
CREEP Maximum UP speed
0 to 50
30
MINimum DOWN speed
0 to 10
2
MAXimum DOWN speed
0 to 100
40
CREEP maximum DOWN speed
0 to 30
10
SWING
ACCELeration
0.5 to 5.0s
2.7
DECELeration
0.1 to 3.0s
1.8
MINimum LEFT speed
0 to 10%
1
MAXimum LEFT speed
0 to 60%
25
CREEP maximum LEFT speed
0 to 35%
15
MINimum RIGHT speed
0 to 10%
1
MAXimum RIGHT speed
0 to 60%
25
CREEP maximum RIGHT speed
0 to 35%
15