JLG 67SL Operator Manual User Manual
Page 40
SECTION 3 - MACHINE CONTROLS
3-8
– JLG Lift –
3121321
Ground Control Descriptions:
1. Platform/Ground Select - This three way keyswitch is
used to select between platform controls or ground con-
trols. When in the center position, the machine is dis-
abled.
2. Engine Start Switch - Toggle Switch used to start engine.
3. Emergency Stop Button - Button, when depressed, will
immediately shut the machine off. Cuts out all functions
except emergency platform lowering.
4. Outrigger Select Switch - Toggle Switch used to select if
outriggers auto leveling function is active or not.
5. Platform Lift/Lower Switch - Toggle switch used to raise
and lower platform.
6. Deck Extend/Retract Switch - Toggle switch used to
extend and retract platform deck extension.
NOTE:
The platform deck extension should be retracted before
lowering the platform.
7. Glow Plug LED - This Yellow LED is off under normal
operating conditions. The LED is illuminated when the
ignition is on and the temperature sensing requires pre-
glow.
NOTE:
Do not start machine when Glow Plug LED is illuminated.
Once the LED goes out, machine starting is permitted.
8. Battery Disconnect Switch - Disconnects ground control
panel from the battery.