beautypg.com

3 operator maintenance, 3 operator maintenance -9 – JLG E300 Operator Manual User Manual

Page 79

background image

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

3121252

– JLG Lift –

6-9

6.3 OPERATOR MAINTENANCE

NOTE: The following numbers correspond to those in Figure 6-

1., Operator Maintenance and Lubrication Diagram.

LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION
UNDER NORMAL CONDITIONS. FOR MACHINES USED IN MULTI-SHIFT
OPERATIONS AND/OR EXPOSED TO HOSTILE ENVIRONMENTS OR CON-
DITIONS, LUBRICATION FREQUENCIES MUST BE INCREASED ACCORD-
INGLY.

1. Swing Bearing

Lube Point(s) - Remote Fitting
Capacity - A/R
Lube - BG
Interval - Every 3 months or 150 hrs of operation
Comments - Apply grease and rotate in 90 degree
intervals until bearing is completely lubricated

Table 6-14. Lubrication Specifications.

KEY

SPECIFICATIONS

MPG

Multipurpose Grease having a minimum dripping point of
350 degrees F. Excellent water resistance and adhesive qual-
ities; and being of extreme pressure type (Timken OK 40
pounds minimum).

EPGL

Extreme Pressure Gear Lube (oil) meeting API Service Clas-
sification GL-5 or Mil-Spec Mil-L-2105.

HO

Hydraulic Oil. Mobil DTE-11M

BG*

Bearing Grease (JLG Part No. 3020029) Mobilith SHA 460.

*MPG may be substituted for these lubricants, if necessary, but service
intervals will be reduced.