Battery Charger Fault (LED Flash)
If a fault has occurred during battery charging, the (AMBER or RED) LED
on the charger LED indicator (See Figure 3-12.) will flash corresponding
to the fault which occurred. Refer to Table 3-1 following for the charger
LED flash codes and their meaning.
If required, further general and troubleshooting information about the
battery charger can be found in the charger manufacturers Owner’s
Guide.
Table 3-1. Battery Charger Fault (LED Flash)
FLASHING LED
FAULT
REMEDY
AMBER
Battery High Voltage
Upon battery voltage >2.5V per cell @ startup, charger shall flash amber LED and not
allow charging - Battery or System problem.
AMBER
Battery Low Voltage
Upon battery voltage <0.17V per cell @ startup, charger shall flash amber LED and
not allow charging - Battery or System problem.
AMBER
Failed Trickle to min V
Should battery fail to reach 1.75V per cell charge shall flash an amber LED until char-
ger is power cycled - Battery or System problem.
RED
Charger Internal Fault
Signals a hardware fault of the charger and shall indicate flashing red LED.