General, Platform on/off key switch, General -16 platform on/off key switch -16 – JLG 15/20MSP Operator Manual User Manual
Page 42

SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
3-16
– JLG Lift –
3121230
General
The following conditions must be met before the machine can be
operated from the platform control console:
• Ground Control Station - Main Power Selector Switch must
be set to PLATFORM CONTROL MODE.
• Ground Control Station - Emergency Stop/Shut Down Button
must be in the RESET position (POWER ON).
NOTE: See Section 3.5 on page 3-7, for Ground Control Station
operation.
• Platform Console - On/Off Key Switch must be set to the ON
position.
• Platform Console - Emergency Stop/Shut Down Button must
be in the RESET position (POWER ON).
• If equipped with the OPTIONAL - PSL (Programmable Secu-
rity Lock - Section 3.12 on page 3-36) it must be set to the
ON position.
NOTE: SLEEP MODE - During operation if no control functions
have been activated for 10 minutes (default programma-
ble setting), the ground control module will power the
machine down to conserve battery power. Cycle power
back on using either the main power selector switch (key)
or the emergency stop/power down button on either the
platform controller or the ground control station.
Platform On/Off Key Switch
Set the ON/OFF Key Switch to the OFF position to power machine
down.
NOTE: If necessary, when machine is not in use, remove key
from platform key switch to disable machine from unau-
thorized use.
NOTE: During operation the operator in the platform can prevent
unauthorized control of the machine (from the Ground
Control Station) by either switching the On/Off Key to the
OFF position, or activating the Emergency Stop Button on
the platform control console.
At the Platform Control Console -
Set the On/Off Key Switch to the
ON position (2) to operate
machine.
1. OFF Position
2. ON Position
1
2