beautypg.com

3 diagnostic menu (le, mrt & rts), Diagnostic menu (le, mrt & rts) -3, Diagnostic menu descriptions (le, mrt & rts) -3 – JLG LSS Scissors User Manual

Page 15

background image

SECTION 2 - OPERATION - (LE, MRT, RTS)

3124288

– JLG Lift –

2-3

2.3 DIAGNOSTIC MENU (LE, MRT & RTS)

The Diagnostic Load Menu is another troubleshooting tool
for the Load Sensing System. Sensor and status informa-
tion is presented in real-time for the technician. Several
sub-menus exist to organize the data.
Note that the Diagnostic Menu changes based on MODEL
Parameter in the Machine Setup Menu (some displays are
suppressed). The information presented in the following
table will be proper when MODEL=3369LE/4069LE/
500RTS or 260MRT (refer to Machine Setup Menu).

To access the Diagnostic Menu, use the LEFT and RIGHT
Arrow keys to select DIAGNOSTICS from the Top Level
Menu. Press the ENTER key to view the menu.
Press the LEFT and RIGHT Arrow keys to view the dis-
plays and select the various sub-menus (PIN 1, PIN 2,
etc.). To access a sub-menu, press the ENTER key. Once
in a sub-menu, press the LEFT and RIGHT Arrow keys to
view the various displays (just like a Top Level menu). To
exit a sub-menu, press the ESC key.
The table below details the structure of the Diagnostic
Menu, and describes the meaning of each piece of infor-
mation presented.

Table 2-2. Diagnostic Menu Descriptions (LE, MRT & RTS)

Diagnostics Menu

(Displayed on Analyzer 1

st

Line)

Parameter (Displayed

on Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description

PLTLOAD

+XXXX LBS or Kg

Displays (Total Measured Force – Empty Platform
Calibration)

PLTGROS

+XXXX LBS or Kg

Displays Total Measured Force (Sum of Pins 1 thru 4
LOAD)

OVERLOADED?

Yes / No

Displays Current LSS Module Overload Status

CELL 1:

LOAD

+XXXX LBS or Kg

Displays Calibrated Cell Reading in Current Units

RDG

+XX.XXXX mV/V

Displays Pin Reading in mV/V

INPUT

+XX.XXXX mV

Displays Pin Reading in mV

GAIN

XXXX.X

Displays calibration factor from pin

CELL 2:

LOAD

+XXXX LBS or Kg

Displays Calibrated Cell Reading in Current Units

RDG

+XX.XXXX mV/V

Displays Pin Reading in mV/V

INPUT

+XX.XXXX mV

Displays Pin Reading in mV

GAIN

XXXX.X

Displays calibration factor from pin

CELL 3:

LOAD

+XXXX LBS or Kg

Displays Calibrated Cell Reading in Current Units

RDG

+XX.XXXX mV/V

Displays Pin Reading in mV/V

INPUT

+XX.XXXX mV

Displays Pin Reading in mV

GAIN

XXXX.X

Displays calibration factor from pin

CELL 4:

LOAD

+XXXX LBS or Kg

Displays Calibrated Cell Reading in Current Units

RDG

+XX.XXXX mV/V

Displays Pin Reading in mV/V

INPUT

+XX.XXXX mV

Displays Pin Reading in mV

GAIN

XXXX.X

Displays calibration factor from pin

SYSTEM:

OVLOAD STAT

OFF / ON

State of Overload Status Digital Output

WARNING

OFF / ON

State of Warning Digital Output

MOT INHIBIT

NO / YES

Status of Internal Motion Inhibit Flag

MOTION #1

OFF / ON

Status of Digital Input #1