JLG X19J Operator Manual User Manual
Page 20

2.1.4.4 ELECTRICAL SYSTEM TECHNICAL SPECIFICATIONS THERMIC
Battery ................................................................................35 Ah ‑ 240 A ‑ 12V
Alternator: petrol engine ..................................................20 A (3600 rpm)
Alternator: diesel engine ..................................................14 A (3000 rpm)
Electric motor: ‑ rated voltage..........................................230 V (110 V optional)
‑ frequency ............................................50 Hz (60 Hz optional)
‑ rated power ........................................2,2 kW
For further information, see wiring diagram enclosed with the manual and the paragraph on
maintenance of electrical components.
2.1.4.5 ELECTRICAL SYSTEM TECHNICAL SPECIFICATIONS LITHIUM
Battery ................................................................................90 Ah ‑ 48V
Electric motor: ‑ rated voltage ......................................48 V
‑ rated power ........................................2 kW
Sound pressure level at operator’s ear ..........................70 dB
Measured sound power level ..........................................86 dB
Guaranteed sound power level ......................................88 dB
Onboard battery charger ..................................................220V±30V 50÷60Hz
Battery charger (option)....................................................110V±30V 50÷60Hz
For further information, see wiring diagram enclosed with the manual and the paragraph on
maintenance of electrical components.
BOOM LIFT MODELS X19J
JLG
16
X19JR0620113