TROUBLESHOOTING

1. Cycle the Preamplifier Tuner’s front panel

POWER switch to OFF then back to ON.

1. It is possible that the Preamplifier

Tuner needs to be reset (cold
power boot).

One or more
channels sound
bad

1. Check for batteries inside remote.
2. Put in fresh batteries.
3. Follow diagram in battery compartment.
4. Clear path to front panel of unit.
5. Clean lens with a soft cloth.
6. Refer to

IR Lock under Security Options in

this manual

1. Batteries missing.
2. Batteries dead.
3. Batteries inserted wrong.
4. Remote signal blocked.
5. Lens requires cleaning.
6. IR Lock is enabled

Remote will not
operate unit.

1. Check all connectors and repair as

necessary.

2. Check ground of outlet. Have it checked by

qualified serviceman.

3. Check ground.
4. Reposition cables.

1. Poor ground connection in

interconnect cables.

2. Poor ground in main

AC

supply.

3. Poor ground on cable box.
4. Cables running across back of

TV

.

Loud hum or buzz
on one or more
channels

1. Unmute Preamplifier Tuner.
2. Increase volume.
3. Select source.
4. Tighten, repair, or replace cable.

5. Tighten, repair, or replace cable.

1. Preamplifier Tuner in mute
2. Volume control to minimum.
3. Wrong source selected.
4. Line stage to amp. cables loose or

faulty.

5. Source to line stage cables loose or

faulty.

No sound, display
on.

1. Reconnect power cord.
2. Check power at plug.
3. Turn power switch on.
4. Check for shorts or overloading. Replace

fuse.

1. Power cord not plugged in.
2. Power off at

AC

source.

3. Power switch off.
4.

AC

power inlet fuse blown or faulty.*

No sound, display
will not light

POSSIBLE SOLUTION

POSSIBLE CAUSE

PROBLEM

* Note

:

If the unit continues to blow power inlet fuses, have the unit checked by a qualified

technician.

DO NOT USE A HIGHER RATED FUSE!

,

contact B&K customer service.

26