Chapter 11 – Troubleshooting

TB47J – 0075239EE

55

Symptom

Constant tone alarm sounds and

engine shuts off.

Horn is sounding intermittently

and the overload light is flashing.

Horn is sounding constantly and

the overload light is on.

Platform overload sense system

does not work while operating the

upper controls.

Boom functions do not immedi-

ately return when switching from

drive to boom. There is a delay in

boom functions after switching the

drive/boom switch to the boom

position after driving the machine

with the boom below horizontal.

All functions stop working.

Lower controls do

not work.

Possible Cause

High engine temperature.

Low oil pressure.

The load in the platform is greater

than the rated capacity.

The platform overload system has an

error.

Drive/boom selector switch is in the

drive position and the main boom is

below horizontal.

System needs calibration.

Platform overload system delay.

Low fluid level in reservoir.

Engine or pump failure.

Circuit breaker is tripped.

Electrical system malfunction.

Platform overload sensor is tripped.

Battery disconnect switch turned off.

Emergency stop switch at lower con-

trols is pushed in to the off position.

Corrective Action

Let the engine cool. Do not restart

the engine until the cause of overheat-

ing has been corrected.

Do not restart the engine until the

cause of low oil pressure has been

corrected. The engine can be re-

started with low oil pressure, but it

will only run a few seconds before it

shuts off again.

Remove load from the platform until

the alarms stop.

Remove load until at or below rated

capacity. Cycle machine power off,

then on. If alarm continues, system

may need recalibration.

Normal operation. The platform over-

load system is inactive while driving

with the boom below horizontal to

prevent accidental activation due to

rough terrain.

Refer the problem to a qualified ser-

vice technician.

Normal operation. The system in-

cludes a 5 second delay to eliminate

rapid stop and restart of movements

if the overload system trips during

operation.

Check fluid level. Add correct type of

fluid if necessary.

Manually stow the machine using the

emergency power system or the

emergency lowering knob.

Push circuit breaker button in to re-

set.

Manually lower the boom using the

emergency lowering knob.

If horn is sounding and red overload

light is on or blinking, remove weight

from the platform until the load is at

or below rated capacity.

Place switch in the on position.

Pull the emergency stop button out

to the on position.