Chapter 11 – Troubleshooting
58
TB80/TB85J Fixed Axle – 0112792
Symptom
Engine will not start from
lower controls.
Engine will not start from
upper controls.
Possible Cause
Switches are set wrong. The engine
will not crank.
The master start switch was left in
the on position for 30 seconds or
longer before turning it to start.
The main system circuit breaker on
the wiring box has tripped. The en-
gine will not crank.
Switches are set wrong. The engine
will not crank.
Platform foot switch is activated.
The master start switch was left in
the on position for 30 seconds or
longer before turning it to start.
Corrective Action
Turn the battery disconnect switch on
and then at the lower controls:
• Turn the master start switch off.
• Pull the emergency stop button
outward.
• Place the controls switch in the
lower control position.
• Place the master start switch in
the on position for 5 seconds and
then turn the switch to start.
Turn the start switch back to off, then
to start within 30 seconds.
Push the main system circuit breaker
button back in. If the button pops back
out, refer the problem to a qualified
service technician.
Turn the battery disconnect switch on
and then at the lower controls:
• Turn the master start switch off.
• Pull the emergency stop button
outward.
• Place the controls switch in the
platform position.
• Place the master start switch in
the on position.
From the upper controls:
• Turn the master start switch off.
• Pull the emergency stop button
outward.
• Place the master start switch in
the on position for 5 seconds and
the then turn the switch to start.
Do not step on foot switch while start-
ing the engine.
Turn the master start switch back to