beautypg.com

Danger – Snorkel S1930CE User Manual

Page 26

background image

Chapter 8 – Prestart Inspection

22

S1930 – 0361518EE

A

Danger

Pinch points may exist between moving compo-

nents. Death or serious injury will result from be-

coming trapped between components, buildings,

structures, or other obstacles. Make sure all person-

nel stand clear of the aerial platform while perform-

ing the prestart inspection.

Test the operation of the platform raise/lower switch in

both directions.

Place the battery disconnect switch in the off position.

The platform should not raise or lower with the discon-

nect in this position.

Emergency Stop

Push the emergency stop button in to turn off the electri-

cal power. The lower control functions should not operate

with the emergency stop in this position.

Lowering Alarm and Interrupt

Raise the platform approximately 3 m (10

′). Lower the

platform and make sure the alarm sounds. The platform

should stop lowering when it reaches about 1.5 m (5

′).

Release the raise/lower toggle switch to reset the lower-

ing function. Wait for 5 seconds and then push the joy-

stick forward to continue lowering.

Pothole Protector Interlock

Perform this test using the lower controls.

1. Stow the aerial platform on a smooth, flat, level con-

crete slab.

2. Remove all persons and materials from the platform.

3. With the trays closed, check the ground clearance

under the pothole protector skids (refer to Figure 8.12).

Clearance should be at about 7 cm (2

3

/

4

″) on both

sides of the aerial platform.

Figure 8.12 – Pothole Protector Skid

4. Raise the platform while watching movement of the

skids. The skids should lower to approximately 2 cm

(

3

/

4

″) ground clearance when the platform is raised

approximately 61 cm (24

″).

Check the wheel lug nuts to see that none are missing,

damaged, or loose.

Ground Strap

Make certain the ground strap (refer to Figure 8.10) is

securely fastened to the chassis. It should be long enough

to contact the ground surface to eliminate static electric-

ity from the machine.

Figure 8.10 – Rear of Chassis

Lower Control Station

With no personnel in the platform, test the operation of

each control from the lower control station (refer to Fig-

ure 8.11).

Figure 8.11 – Lower Controls

Operating Controls

Use the following procedure to operate the machine from

the lower controls.

1. Turn the battery disconnect switch on.

2. At the lower controls, pull the emergency stop switch

outward to the on position.

3. Insert the key into the control selector switch and

turn the switch to the lower controls position.

Ground Strap

Emergency Stop Button

Control Selector Switch

Platform Raise/Lower Switch

Pothole Protector Skid