Daily inspection and maintenance, Daily inspection and maintenance table 7-1, Daily inspection and maintenance table, 7-1 – Snorkel EPV12J User Manual
Page 37: Operators daily inspection, 7-1, Inspection and maintenance table, 7-1, Qualified, 7-1, 8-2, Daily inspection and maintenance table -1, Danger

7. Daily Inspection and Maintenance
At the start of each work day (or 8 hour shift), an
EPV12J qual i fied op er a tor must per form the Daily
In spec tion and Main te nance as listed in the ta ble
be low.
The pur pose of the Daily In spec tion and Main te -
nance is to keep the EPV12J in proper work ing
con di tion and to de tect signs of mal func tion at the
ear li est pos si ble time.
The EPV12J should be in the STOWED POSITION
and the Mas ter Key Switch set to OFF be fore you
be gin this in spec tion.
De fec tive parts and/or equip ment mal func tions
jeop ar dize the safety of the op er a tor and other per -
son nel, and can cause dam age to the ma chine.
DO NOT operate an EPV12J that is known to
be damaged or malfunctioning.
R e p a i r a l l e q u i p m e n t d a m a g e o r
malfunctions, before placing the EPV12J
into service.
EPV12J – 12246A
page 7 - 1
Item
Service Required
Engine fuel level
Look to see that the fuel tank is full
Fuel tank cap
Check to see that the cap is tight
Engine oil level
Check oil level (between dipstick lines)
Fuel leaks
Visually inspect (hoses and connections)
Engine coolant
Check that grills are not blocked
Wiring harnesses
Visually inspect (installation, condition)
Battery terminals
Visually inspect (no corrosion)
Battery fluid level
Check fluid level (1/4" or 6 mm below filler neck)
Hydraulic oil level
Visually inspect level (between lines on gauge)
Hydraulic oil leaks
Visually inspect (hoses, tubes)
Bolts and fasteners
Visually inspect (condition)
Structural damage and welds
Visually inspect (weld cracks, dents)
Lanyard anchor points
Visually inspect (condition)
Platform gravity gate
Check condition and operation
Platform guardrails
Visually inspect (condition)
Flashing light (option)
Visually inspect (operation)
Ground control switches
Actuate and inspect for proper operation
Level sensor (option)
Check operation
Emergency lower
Check operation (causes correct motion)
Platform control box switches
Actuate and inspect for proper operation
RCD/ELCB AC outlet (option)
Check operation
Platform work lights (option)
Check operation
Placards and decals
Visually inspect (installation, condition)
■ Daily Inspection and Maintenance Table
DANGER