beautypg.com

Micropump GM Series Service Instructions User Manual

Page 8

background image

MICROPUMP, INC.

A Unit of IDEX Corporation

PO Box 8975, Vancouver, WA 98668-8975 • Phone: 360/253-2008 • Fax: 360/253-8294

MICROPUMP

LIMITED

A Subsidiary of Micropump, Inc.

Howard Road, Eaton Socon, St.

Neots, Cambridgeshire, PE 19 8ET England, • Phone: (44) (0) 1480-356600• Fax: (44) (0) 1480-35630

0

REVISION

LTR.

DESCRIPTION

DATE

BY

A

ORIGINATED PER E14164

1/28/04

CMA

PART NUMBER:

L23154

Page 8 of 9



Note: Pumps with Teflon o-rings may require screws to be tightened 2 to 3

times, due to the hardness of the Teflon material.


7.10

If an elastomer o-ring is used, apply a light even film of Dow Corning
vacuum grease or equivalent (do not use on Teflon seals). Apply grease from capsule to
the thumb and index finger of one hand, and transfer a light even film to the surface by
rubbing o-ring between thumb and index finger. Check that entire surface of o-ring is
coated with vacuum grease.


7.11 Install one o-ring (11) into the pump body (10) o-ring groove. Teflon

o-rings may require slight stretching in order to fit into grooves.

7.12

Position driven magnet (12) on driving gear (6) shaft, aligning magnet set

screw with flat of shaft. Locate driven magnet at a set height of .375” (9.5
mm) as shown in Figure 1, and tighten set screw on flat of shaft.

7.13

Check that driven magnet (12) is free of metal particles (see cleaning

instructions, section 5). Check that driving gear (6) shaft rotates

without sticking (see repair instructions, section 6.5.5).

7.14

Install magnet cup (13) over driven magnet (12), onto o-ring (11) in pump

body.

7.15

Complete the pump assembly with 16 screws (15) (8 screws for low

pressure version) installed through the drive housing (14) and into the

pump body (10). Torque to 30-35 in-lbs It is advised to apply a light oil

to screw threads and under screw head before installation.

7.16

Check that all screws are seated. There should not be any gaps between

mating parts.


8

Pump to Motor Assembly

8.1

The hub assembly should be attached to the motor shaft using key and set

screw. The hub assembly is designed so that when placed on the motor

shaft it will automatically bottom out at the proper setting

8.2

Install pump assembly onto motor. Care should be taken to disallow the

hub assembly from impacting the magnet cup due to high magnetic

attraction.