9.3 Repairs
9.3.1 Coupling replacement
The couplings must be replaced in the event of:
- external damage
- the locking device not working
- hydraulic fluid continually leaking in a coupled/uncoupled state.
WARNING / DANGER / CAUTION!
Never repair couplings: they are to be replaced by original LUKAS parts.
During installation, tighten the coupling to a torque of M
A
= 40 Nm.
Procedure:
1. Remove the coupling.
2. Fit the new coupling and screw it in with a torque of M
A
= 40 Nm.
9.3.7 Labels
All damaged and/or illegible labels (safety notices, type plate, etc.) must be renewed.
Procedure:
1. Remove damaged and/or illegible labels.
2. Clean the surfaces using industrial alcohol.
3. Attach new labels.
Make sure that the labels are attached in the right position. If you are no longer sure about