Lukas CT7 User Manual
Page 17

17
3. Move the lever on the manual pressure shut-off valve
into the working position (turn anti-clockwise to the
stop).
2. Then start the hydraulic unit.
After the hydraulic implements have been bled, your
rerailing system is ready for operation.
6.3 Control desk controls
6.3.1 Controlling single-acting hydraulic devices
To supply single-acting hydraulic devices with
hydraulic fluid, you need to press the relevant button.
As soon as the button is released, fluid stops
being supplied to the associated hydraulic device.
WARNING / DANGER / CAUTION!
In the interests of safety, control desk functions
should not remain enabled (manual pressure
shut-off valve opened) unless at least one
appropriately trained operator is manning the
control desk.
For emergency use, a single handle is
provided to close the pressure shut-off
valve. This shuts off the hydraulic circuit to
all implements. The pressure shut-off valve
interrupts only the hydraulic supply between
the control desk and the pump. It is NOT
provided as an “emergency stop” function.