9.10 General remark
When the connected rescue tool is not needed for a longer period of time, open the dump valve
(see picture 8) and switch the pump off so as to save battery capacity.
10
Maintenance
10.1 Pump unit
After each operation all components have to be checked on proper function (clean them first if
necessary):
- check whether hydraulic fittings and couplers are tightened; tighten them if necessary
- check pump unit, metal hood, battery housing, valves and hoses on external damage
- check whether all signs, warning labels and switching symbols are complete and legible
- check the oil tank on correct oil level (see chapter 10.3)
- check the unit on oil leakage. Defective seals must be replaced immediately.
10.2 Hydraulic tightness
Check the unit on oil leakage and make sure that eventually damaged seals are replaced
immediately.
10.3 Checking hydraulic oil
Attention: Carry out the following procedure over an oil pan and dispose of used oil according to
local regulations and laws !
The P 600 OB is filled with hydraulic oil viscosity class HLP 22.
-
check oil level in the reservoir after each operation; refill/drain oil if necessary (observe
LUKAS oil recommendation 10.5)
-
change hydraulic oil after approx. 50 operations, however after 2 years at the latest
Remark: Select type of hydraulic oil according to prevailing ambient temperature
conditions (see LUKAS oil recommendation10.5)
Bild 12
12.2
12.1
12.4
12.3
13.1
Bild 13
Bild 14