beautypg.com

14 troubleshooting – Lukas LSP 80 EN User Manual

Page 12

background image

12

13.3.5 Labels
All damaged or illegible indentification stickers (Safety instructions, type label a.s.o) have to be
replaced.
Procedure:
Remove damaged stickers and clean surface with acetone • Put on new stickers.

13.3.6 Quick couplers
Quick couplers on the 0,5m hoses have to be replaced when
- external damage can be observed
- the locking sleeve doesn´work any more
- oil spill occurs even when the coupling is properly connected
Remark: Faulty couplers have to be changed completely against genuine LUKAS spares, i.e. it
is not permissible to make any repair work.
The retaining nut on the hoses has to be tightened with a torque of M

A

= 45 Nm

13.3.7 Hood of the valve block
If the hood is damaged so seriously that the star grip doesn´t return any more to zero position
automatically the valve has to be replaced completely or the hood has to be replaced by a authorized
LUKAS dealer or the LUKAS service department.

14

Troubleshooting

If the defects cannot be repaired, contact an authorized LUKAS dealer or the LUKAS service
department. The address:
LUKAS Hydraulik GmbH, Weinstraße 39, D-91058 Erlangen, Pf 2560, D-91013 Erlangen, service
phone 09131/698 348; fax 09131/698 353.

Trouble

Check

Cause

Remedy

Hoses cannot be

Pressurized

Relieve pump pressure

coupled
On actuating blades

Hoses correctly

Air in the hydraulic

Thoroughly vent pump

move slowly or by

connected power

system

unit: see 9.1.1

jerkspack operating
No pressure build-up

Not enough oil in hand

Refill oil and vent the

resp. motor pump.

system (see operating

Vent pumpe after

instruction 9.1.1)

changing oil

Star grip doesn't return

Return spring is

Ask authorized dealer or

to center position when

damaged or return

LUKAS themselves

released

mechanism is dirty

for repair

Oil leakage out of

Untightness, eventually

Replace hoses

hoses or hose fittings

damages

Surface of hydraulic

Contact with

Change hoses

hoses is dissolved

agressive fluids

Leakages on the

Seal defective piston

Replacement of seals

piston rod

rod

by authorized dealer or

LUKAS themselves

This manual is related to the following products: