1
All of the zones on the Super Switch are “normally closed” zones.
2
The maximum loop resistance cannot exceed 3K ohms (If the loop resistance
exceeds 3K ohms and the existing panel used end of line resistance, then the
end of line resistor may be removed).
3
Different control panels have different terminals for each zone and aux power.
Please refer to the wiring diagrams that came with the existing panels. For
example, the HI side of Zone 1—Zone 8 on a “Vista” panel is typically terminals
8,11,12,14,15,17,18, and 20. AUX positive is typically terminal 5 on a “Vista”
panel.
WARNING:
The Super Switch CANNOT be used to monitor any type of fire
or CO Detection Zones.
Specifications
Regulatory Compliance
This device complies with Part 15 of the FCC's Rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
This product complies with FCC radiation exposure limits for an
uncontrolled environment. Avoid operating this product at a distance
less than 20 cm from user.
Caution: Any changed or modifications not expressly approved by the
party responsible for compliance could void the user's authority to
operate this equipment.
Limited Warranty
This 2GIG Technologies product is warranted against defects in
material and workmanship for 2 years. This warranty extends only to
wholesale customers who buy direct from 2GIG Technologies or
through 2GIG Technologies’ normal distribution channels. 2GIG
Technologies does not warrant this product to consumers. Consumers
should inquire from their selling dealer as to the nature of the dealer’s
warranty, if any.
There are no obligations or liabilities on the part of 2GIG Technologies
for consequential damages arising out of or in connection with use or
performance of this product or other indirect damages with respect to
loss of property, revenue, or profit, or cost of removal, installation, or
reinstallation. All implied warranties for functionality, are valid only
until the warranty expires. This 2GIG Technologies Warranty is in lieu
of all other warranties expressed or implied.
For technical support in the USA and Canada:
855‐2GIG‐TECH (855‐244‐4832)
Email: [email protected]
Internet: dealer.2gig.com
Visit web site for technical support hours of operation
For technical support outside of the USA and Canada:
Contact your regional distributor
Visit dealer.2gig.com for a list of distributors in your region
PN: 77‐000009‐001
Wireless Signal Range
350 ft, open air, with 2GIG Wireless Control Panel
Code Outputs
For each of 8 serialized zones: Fault; Restore;
Tamper; Low Battery
Transmitter Frequency
345.000 MHz (crystal controlled)
Transmitter Frequency
Tolerance
±15kHz
Transmitter Bandwidth
24kHz
Modulation Type
Amplitude Shift Keying‐On/Off Keying (ASK‐OOK)
Unique ID Codes
Over one million different code combinations
Supervisory Interval
70 minutes
Peak Field Strength
Typical 50,000 uV/m at 3m
Sensor Dimensions (LxWxH)
3.54 x 2.56 x 1.13 in. (9.0 x 6.5 x 2.9 cm)
Weight (including bracket)
2.85 oz. (80.8 g)
Housing Material
ABS plastic
Color
White
Operating Temperature Limits 32° to 120° F (0° to 49° C)
Relative Humidity
5‐95% Non‐Condensing
Operating Voltage
9‐16 volts DC, 50mA
Included Accessories
Mounting plate, 2 Phillip’s head screws, 2 plastic
drywall anchors