2GIG GB1-345 Glass Break User Manual
Glass break detector, Install instructions, Box contents
GLASS BREAK DETECTOR
INSTALL INSTRUCTIONS
The Glass Break Detector is a fully supervised, tamper‐protected, ceiling
or wall‐mounted unit with 15 feet maximum detection range,
360°maximum horizontal sensing angle, and dual‐stage glass break
detection.
Box Contents
•
Mounting base
•
Sensor
•
2 Lithium batteries
•
3 Phillips head screws
•
3 Wall anchors (plastic)
Programming
The following steps describe general guidelines for programming
(learning) the Glass Break Detector into the Control Panel. Scroll between
op ons using the ← and → arrows. Move to the previous or next prompt
by pressing the ↑ and ↓ arrows.
1
Select RF sensor # (01 to 48). Assign the Glass Break Detector to a
new zone.
2
Select RF sensor type:
(03) glass break
3
Select RF sensor equipment code. Enter 5853 for the Glass Break
Detector.
4
Select RF equipment type.
(1) contact
5
Enter RF sensor serial number (7 digits).
Manual Entry: Type in the last 7 digits of the TX ID that is found
outside of the box or on the back of the device.
Auto Entry: With the panel in Learn‐in mode, (press Shift then Learn)
press the tamper switch. The correct TX ID should appear. Accept the
correct TX ID by pressing ok.
Remember to press the ↓ arrow to continue going through the
system configuration prompts.
6
Select RF sensor equipment age (0 to 1).
(0) new (product is new)
(1) existing (product already exists)
7
Select RF sensor loop number (1 to 3).
8
Select RF Sensor dialer delay (0 to 1)
(0) disabled
9
Construct RF sensor voice descriptor. Press Insert then press any
number between 002 and 255 to add a word. Repeat this for each
word. For example, if you want to name this Glass Break Detector as
the “master bedroom,” press Insert then press 140 for master. Press
Insert then press 024 for bedroom.
10
Select RF sensor reports (0 to 1).
(0) disabled (Glass Break Detector does NOT report to central station)
(1) enabled (Glass Break Detector reports to central station)
11
Select RF sensor supervised (0 to 1)
(0) disabled (detector does not report loss of supervision/low battery)
(1) enabled (detector reports loss of supervision/low battery)
12
Select RF sensor chime (0 to 13).
(0) disabled (panel will NOT chime when Glass Break Detector is
activated)
(1‐13) enabled (selects a voice and chime to sound on the panel when
the Glass Break Detector is activated)
13
To program another sensor click next.
14
To exit programming, click skip then end and exit. Upon exit, the
panel takes several seconds to reboot.
Testing
Walk Test
1
Push the test button for 2 seconds
and then release it. The red LED
appears while the button is pressed.
2
The green LED will blink once to
indicate that the unit is in auto test
mode for 90 seconds.
3
Activate a glass break simulator in the
area of the window or windows that
you are attempting to protect with
the glass break detector. The Glass Break Detector should first
acknowledge the detection of a thud sound by illuminating the green
LED and then illuminate the red LED when the unit detects the crash
portion of the glass breaking sound.
RF Test
•
Push and hold the test button for 5 seconds and then release it. The
red LED appears while the button is pressed. The green LED will blink
twice to indicate that the unit is in RF test mode for 90 seconds.
NOTE:
Perform a system test (per the User Guide) at least once a
year.
Glass Type/Thickness
Minimum size for all glass types is 11” x 11” (28cm x 28cm) square; glass
must be framed in the wall of the room or mounted in a barrier of 36”
(.9 m).
† Sealed insula ng glass types are protected only if both plates of glass
are broken.
TIP:
When wall mounted, the Glass Break Detector is designed to
provide coverage on the opposite or adjacent windows and not
on windows on the same wall as the Glass Break Detector.
Installation
1
Hold the 2GIG‐GB1‐345 Glass Break
Detector unit upside down and twist the
base counter clockwise to remove it.
2
Install recommended batteries making
sure to observe the correct polarity.
3
Wait 5 seconds for the power up delay.
4
Enter the programming mode for a
wireless device on the 2GIG alarm
control panel.
5
Learn the Glass Break Detector into the
Control Panel by pressing and holding the tamper switch for 2
seconds.
Type
Minimum to Maximum Thickness
Plate
1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
Tempered
1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
Sealed Insula ng†
1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)
FCC ID: WDQ‐GB1345
Industry Canada ID: 7794A‐GB1345