Installing the airdog, Fp-150 high flow suction tube – PureFlow AirDog FP-150 - GM Duramax 2001-2010 User Manual
Page 15
15
AirDog
®
FP-100 & FP-150 2001-2010 DuraMax Diesel
Section 5-D High Flow Suction Tube
INSTALLING THE AIRDOG
®
FP-150
HIGH FLOW SUCTION TUBE
NOTE: THE FUEL TANK USED FOR THE FOLLOWING PICTURES IS AN EXAMPLE
ONLY AND MAY NOT BE EXACTLY THE SAME AS YOUR TANK.
The AirDog
®
150 includes a ½” High Flow suction tube to accommodate the high flows of this
system. To install the ½ suction tube it is necessary to either drop the fuel tank or to lift the
truck bed.
NOTE: Should you choose to drop the fuel tank, support the tank as it is when it is installed on
the truck. If you let it rest flat on the floor, the tank may squash out and the suction tube will be
too short after the tank is re-installed in the truck. The suction tube, being cut too short may
suck air as the fuel drops below ¼ tank level.
Figure 26
Figure 27
NOTE: Should you choose to pull the pickup bed to access
the tank, be sure to disconnect the tail light wires,
fuel tank filler tube, and any other accessories or
components that may be secured to the frame and bed.
When Dropping the Tank, Always Remember Safety First!
If you choose to remove the bed, properly support the truck bed to prevent
serious injury or death!
Figure 28
Figure 29
NOTE: THE TRUCK BED USED FOR THE FOLLOWING PICTURES IS FOR
EXAMPLE ONLY AND MAY NOT BE EXACTLY THE SAME AS YOUR
TRUCK BED.