Problem 1
Heater
does not
light
Is
thermostatic
head set t
o
maximum?
Is the
primar
y orif
ice
plugged on the
Inside or
outside?
Turn thermostat
up t
o
Its
maximum
setpoint.
R
emo
v
e
the primar
y burner
oif
ice. Clean with a sof
t brush
or com
pressed air
.
Ye
s
No
Ye
s
Ye
s
Ye
s
Is the inner
combustion cone
plugged?
Is there air or
a block
age in the
gas hose or
gas piping?
R
emo
v
e
block
age with com
pressed
air or replace the gas hose or pipe
section. Bleed of
f an
y air fr
om the
gas line.
Clean the heat
er
.
Clean the heat
er
.
No
No
No
Is pr
oper
gas pressure
supplied t
o
the
zone panel or
heat
er?
Pr
o
vide 5 PSIG
gas pressure.
Ye
s
No
Are all fuel
supply v
alv
es t
o
heat
er
open?
Open all fuel
supply v
alv
es.
Ye
s
No
Def
ectiv
e
saf
ety contr
ol v
alv
e.
R
eplace the saf
ety
contr
ol v
alv
e.
Ye
s
No
Problem 2
Flame burning
beyond outer
cone, or lazy
flame
Tight
en the
burner nuts.
Ha
v
e
heat
er and
filt
er been pr
operly
cleaned?
Clean the heaqt
er
and f
ilt
er
.
Ye
s
No
Is pr
oper
gas pressure
supplied t
o
the
zone panel or
heat
er?
Pr
o
vide 5 PSIG
gas pressure.
Ye
s
No
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 350 Premier Dual Fuel (33 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)