TROUBLE-SHOOTING CHART
18
Fluid Management
®
An excessive amount of
vibration occurs.
if mixer is out of balance.
• Balance by adjusting the
legs.
if adjustable leg is broken or dam-
aged.
• Replace adjustable leg.
The POWER light is on
and nothing happens.
if the motor connections.
• Tighten motor
connections as required.
for broken wire motor cabling.
• Replace motor cable as
needed.
for faulty contact block on power
switch.
• Replace motor cable as
needed.
for problem with the motor.
• Replace motor.
for problem with printed circuit
board.
• Call Customer Service.
Replace printed circuit
board.
The POWER light does not
turn on and nothing hap-
pens.
for problem with POWER switch,
light or operator button.
• Replace as needed.
The POWER light does not
turn on and mixer runs nor-
mally.
for problem with POWER switch,
light.
• Replace as needed.
The mixer starts slowly
and then increases to nor-
mal speed in a few sec-
onds.
shake motor V-belt tension.
• Adjust the shake motor V-
belt tension.
The mixer speeds up and
slows down.
if the door is making partial con-
tact with the safety switch.
• Adjust safety switch.
for a damaged wire in motor
cabling.
• Replace motor cable.