TROUBLE-SHOOTING CHART
20
Fluid Management
®
An excessive amount of
vibration occurs.
if mixer is out of balance.
• Balance by adjusting the
legs.
if adjustable leg is broken or dam-
aged.
• Replace adjustable leg.
The power is on and noth-
ing happens.
the motor connections.
• Tighten motor
connections as required.
for broken wire motor cabling.
• Replace motor cable as
needed.
for faulty contact block on power
switch.
• Replace contact block as
needed.
for problem with the motor.
• Replace motor.
for problem with printed circuit
board.
• Call Customer Service.
Replace printed circuit
board.
for problem with POWER switch
• Replace as needed.
The mixer starts slowly
and then increases to nor-
mal speed in a few sec-
onds.
belt tension.
• Adjust the belt tension.
The mixer speeds up and
slows down.
for the door is making partial con-
tact with the safety switch.
• Adjust safety switch.
for a damaged wire in motor
cabling.