Frequently asked questions, Equipment troubleshooting – Fluid Management 1500HS Accutinter User Manual
Page 36

Fluid Management Customer Service 1 . 800 . 462 . 2466
34 | Accutinter 1500
Frequently Asked Questions
Equipment troubleshooting
PROBLEM
FIRST CHECK:
ACTION
The machine is
dispensing mis-tints.
…Do the fill settings in
ColorPro match what is
inside the canister?
…Have the nozzle openings
been cleaned recently?
…Is the Accutinter dispensing
accurately?
Compare the canister
contents with the fill
settings. Adjust if necessary:
1- Look inside the canister
and compare the contents
with what the fill settings in
ColorPro show.
2- If they do not match, fill
the canister and adjust the
colorant level in ColorPro
(
see page 17
).
Clean the nozzles:
1- Clean each nozzle opening
with a nozzle cleaning tool.
2- Remove all excess colorant
from around the nozzles
(
see page 33/34
).
3- Purge the lines with
ColorPro (
see page 28
).
4- Repeat cleaning and
purging if necessary.
Dispense one ounce of
each colorant into a marked
measuring container. If you
notice any colorants are not
dispensing, call
Customer
Service for assistance.
The colorant shoots to the
side during a dispense.
…Have the nozzles been
cleaned recently?
1- Clean the nozzle. Remove
all excess colorant and
dried debris.
2- Purge the colorant line.
3- Repeat if necessary.
Most of the problems listed in this section can be prevented by daily cleaning and by purging the nozzle.
See the
Maintenance, Care and Use section in this manual for instructions.
Use the chart below to locate the problem and perform the recommended actions in the last column.
Contact