Using the INCREASE and DE-
CREASE buttons ( or ), set the flow
rate to the actual known flow rate.
6.
Press the DISPLAY (
i
) button to view
the water flow calibration factor. (See
Figure 5.) Write this number down for
future reference.
7.
Press and hold the DISPLAY (
i
)
button until PASS is shown. (See
Figure 1 on the preceding page.)
8.
With the DISPLAY button (
i
) pressed,
press the INCREASE ( ) button 4
times.
A u is shown with each INCREASE
button press. (See Figure 6 in the
next column.)
DDDDD
DDDDD
9.
Release the DISPLAY (
i
) button. The
display shows ScAL for approximately
5 seconds. The unit is reinitialized
and the calibration factor is saved.
(See Figure 7.)
10.
Water flow calibration is complete.
Manual p/n: 113968 Rev -, 04/11/2006