Figure a-4: lifting separator tank, Panel strainer, water cooling, A.3 plumbing connections – Hale SMR-U User Manual
Page 40: Plumbing connections
❑ SMR-AC Installation and Setup
54
Addendum - SMR-AC CAFSPro Installation Guide
p/n: 029-0020-78-0
Attach female eye-bolts, 12 mm, to the
top cross bracket mounting studs for
lifting. Mount the separator tank hav-
ing the inlet port sightly BELOW the
compressor discharge port to ensure
back-flush does not enter the com-
pressor, which would severely damage
the unit. (See Figure A-4: “Lifting Sep-
arator Tank.”)
Mount the tank using 7/16”-14, Grade
8 screws, flat and lock washers and
nuts. For a separator tank mounting
overview schematic, see Section
“Drawing Package” on page 67.
Panel Strainer, Water Cooling
For mounting instructions, see Section 4.4 “Panel Strainer” on page 21.
A.3
PLUMBING CONNECTIONS
(See Figure A-5: “Overview, SMR-AC System Connections,” on page 55.)
The following connections are made by the system builder/installer:
❑
Truck air to solenoid manifold
❑
Gearbox cooler return line to booster tank
❑
Pressure lines (3/8” tube) to PM control
❑
Control line (3/8” tube) from PM control to sensing valve
❑
Switch and truck air to pump master drain
❑
Water and air to duplex master gauge
❑
TRV electrical and discharge connections
❑
TPM electrical connections
Figure A-4: Lifting Separator
Tank