Bryant 619CNF User Manual

Page 4

background image

—4—

Table 3B — Physical Data, Under Ceiling Heat Pump Units

*Field reconfigured to 18,000 Btuh (1

1

/

2

tons). See Before Installation

section on page 3 for details.

†The valve connection size is

7

/

8

inch. The recommended line size is

1

1

/

8

inch.

3. Remove inlet grilles from indoor unit by sliding for-

ward. Reinstall prior to unit start-up.

IMPORTANT: If necessary, reconfigure the 24,000 Btuh fan coil
unit to 18,000 Btuh. Unplug the fan motor at the control box
harness and plug into the 619CN018 marked connector.

II. STEP 2 — SELECT LOCATION

Consult local building codes and NEC for special installation
requirements. See Fig. 3 and 4 for unit dimensions and
required clearances.

There are several ways the unit may be installed to different
types of ceiling construction. These instructions do not cover
all installation methods. As a typical installation, these
instructions focus primarily on mounting the unit to metal in

new construction. Plan the installation carefully before you
begin. Listed below are some guidelines that should be fol-
lowed when determining location for the unit.

1. Place unit adjacent to an outside wall if fresh air is

required, ensuring that location allows for complete
air distribution.

2. Locate the thermostat in an area that is not subjected

to drafts or direct sunlight through windows. Locate
the thermostat on an internal wall whenever possible.

3. Allow sufficient clearance for airflow, wiring, refriger-

ant piping, and servicing unit (Fig. 3 and 4).

4. Make sure the unit is easily accessible to electrical

power.

UNIT SIZE

018*

024

030

036

048

060

NOMINAL CAPACITY (tons)

1

1

/

2

2

3

3

4

5

NOMINAL SIZE (Btuh)

18,000

24,000

30,000

36,000

48,000

60,000

OPERATING WEIGHT (lb)

110

110

119

119

151

181

MOISTURE REMOVAL WEIGHT
(Pints/Hr)

4.0

7.3

6.0

9.0

13.0

14.5

FINISH

GM Motorhome White with Black Trim

REFRIGERANT

R-410A

Control (Cooling)

AccuRater Control

TXV

INDOOR FAN

Direct Drive Centrifugal

Rpm...Cfm High

900…480

1050…550

1275...840

1275...840

1435...1130

1275...1600

Rpm...Cfm Medium

862...400

900…480

972...740

972...740

1388... 975

972...1220

Rpm...Cfm Low

770...320

862...400

830...640

830...640

1315... 820

830...1040

High Speed Watts

92

92

282

282

425

564

Motor Quantity

1

1

1

1

2

2

Blowers — No. ...Size (in.)

2...6x8

2...6x8

2...6x8

2...6x8

3...6x8

4...6x8

INDOOR COIL

Copper Tube, Aluminum Fin

Face Area (sq ft)

2.2

2.2

2.6

2.6

3.0

4.0

No. of Rows

4

4

4

4

4

4

Fins/in.

14.9

14.9

14.9

14.9

14.9

14.9

Circuits

4

4

4

4

8

8

FILTERS

Cleanable

Quantity

4

4

5

5

6

8

HEATERS (kW)

2.0

2.0

3.0

3.0

4.0

5.0

AIRSWEEP

Horizontal

User select ON/OFF

Vertical

Manual

CONTROLS

Control Voltage

24 V

Defrost Method

Timed

Dehumidification

Yes

Auto Restart

Yes

Fan Speed

High/Medium/Low

Condensate Pump Safety

Yes (Accessory)

Filter Change Indication

250 Hours of Indoor Fan Operation

Freeze Protection

Indoor coil less than 28 F, resets at 50 F.

REFRIGERANT LINES

Connection Type

Flare

Liquid Line OD (in.)

3

/

8

Vapor Line OD (in.)

5

/

8

5

/

8

3

/

4

3

/

4

7

/

8

7

/

8

Max Line Length

For maximum line lengths see condensing unit instructions.

CONDENSATE DRAIN
CONNECTION

Pipe Thread (MPT)

CONDENSATE DRAIN SIZE (in.)

3

/

4