Rinse Alarm Feature

Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum

performance of the dispenser. The automated Rinse Alarm feature has two levels of operation, Disabled and

Warning.

Alarm Level Selected

Alarm Mode

Disabled None

Warning

Rinse LED will come on 4 hrs prior to the selected time interval and remain on

until the Rinse procedure has been performed. The dispenser will continue to

serve product.

NOTE: The time interval between Rinses is adjustable from 0 to 24 hrs.

The dispenser is shipped with the automated Rinse Alarm disabled, (No Alarm). It is up to the user to determine the

Rinse time interval and the level of warning required, based on their application and maintenance procedures.

To enable the automated Rinse Alarm feature, refer to RINSE ALARM in Programming the Dispenser.

Rinse Procedure:

1. Open the cabinet door and select Rinse on the Function Selector switch – close the door.

2. Place a 2 Liter (1/2 Gal) container under the Left dispense tip.

3. Press and hold the Left dispenser until water flow stops automatically, approximately 20 sec.

4. Repeat Steps 2 & 3 for the Right dispense tip.

NOTE: The Rinse LED will turn OFF, when the Rinse procedure has been satisfied for both sides.

5. Open the cabinet door and select Normal on the Function Selector switch – close the door.