Bunn JDF-2S User Manual
Page 21

21
TROUBLESHOOTING (cont.)
Dispense station not working
All stations dispense concentrate
only
1. Dispense Lockout switch set to
OFF position.
2. Dispense switch failed
Main water supply
Frozen bath
Inlet water valve failed
Place switch in ON position.
Check switch and harness for proper
continuity.
Check for ON position.
A) Compressor relay/contacts
shorted - replace relay.
B) Recirculating pump - replace or
check for kinked flex line.
A) Check for 120V or 230V power
when dispensing. If yes, replace
valve. If no, check harness for
proper continuity. Then replace
circuit board if needed.
PROBLEM
PROBABLE CAUSE
REMEDY
44744 032811
See also other documents in the category Bunn Water equipment:
- TDO-3.5 (2 pages)
- AF PR-2 (18 pages)
- TDS3 (2 pages)
- TCD (3 pages)
- ULTRA-1 (17 pages)
- ULTRA-1 (2 pages)
- TDS-5S (3 pages)
- EASY CLEAR H5E (2 pages)
- AFPO-2 SL (25 pages)
- EASY CLEAR EQ-12-TH (2 pages)
- WATER QUALITY SYSTEM EQHP-25L (2 pages)
- EASY CLEAR EQ-17-TL (2 pages)
- HW2 (4 pages)
- LCA-2 (22 pages)
- LCA-2 LP 38791.0000K (26 pages)
- HW2A (4 pages)
- ULTRA-2 (23 pages)
- FMD-2 (2 pages)
- SILVER SERIES JDF-2S (28 pages)
- FCD-4 (21 pages)
- EASY CLEAR EQHP-ESP (2 pages)
- FMDS-3 (2 pages)
- TDO-N-4.0LP (2 pages)
- ULTRA-2 PAFA (4 pages)
- JDF-2 (21 pages)
- LCR-2C (2 pages)
- TCD-2 (18 pages)
- FMD DBC-3 4-CUP (4 pages)
- LCR-3 (27 pages)
- EQHP-10L (2 pages)
- 2 (3 pages)
- Water Quality System EQHP-35L (2 pages)
- Chilled LCC-2 (26 pages)
- TDO-4T TDO-5 (2 pages)
- ICD3 (3 pages)
- Water Quality System EQHP-TWIN 108SP (2 pages)
- TCD-1 (2 pages)
- TDO-N (2 pages)
- FMD-5 (45 pages)
- JDF-4S (2 pages)
- AFPO-3 SL (25 pages)
- Complete Store Water Quality Systems EQHP-TWIN 70L (2 pages)
- EDSS-11-T200F (2 pages)
- TDO-N-3.5 (2 pages)