beautypg.com

Bunn JDF-2S User Manual

Page 24

background image

24

TROUBLESHOOTING (cont.)

Unit is not working

Difficulty brixing and/or weak bev-

erage

Difficulty brixing and/or weak bev-

erage

Difficulty brixing bag-in-box

1. Step-down transformer.

2. Main control board.

1. Product viscosity or too cold.

2. Low water pressure.

3. High water pressure.

4. Dispense valve adjustment set-

ting.

5. Brix ratio.

1. Pump tubing.

2. Use of portable water pump.

Vacuum leak

Check for 120/24 or 230/24 vac. If no

24vac reading, replace step-down

transformer.

If 24 vac present and no LED’s lit,

replace control board..

Thorough thaw of product before

use (35° - 40°)

Maintain 20 psi or higher and a

minimum flow rate of 3 fl oz/sec.

Over 100 psi, install a pressure

regulator and set to 50 psi.

A) Perform 3 second water dispense

test. Factory setting is 1.0 oz/sec.

Acceptable water flow rate is .-0.8

to 1.5 oz/sec depending on the mix

ratio (4+1).

B) Adjust water to proper mix ratio.

Once water is set, adjust motor

speed to achieve brix %.

Check for proper brix ratio per prod-

uct using Total Dispense method

and or refractometer method.

Inspect, clean, or replace tubing

and pump rotor/rollers for ease of

rotation.

A) Follow plumbing requirements

for pressure and flow rate.

B) Source another portable pump

or water supply that meets require-

ments.

Inspect all lines and connections

from bag-in-box connector to bottle

adapter assembly.

PROBLEM

PROBABLE CAUSE

REMEDY

44744 032811