Start a telnet session on the mobile station to, Navigate through the aironet access point menu, Set up the test options to accurately model th – Aironet Lan Adapter User Manual
Page 71: Set the test for continuous operation with a 1, Begin traversing the area around the aironet 1

Utilities
4-3
8.
Start a telnet session on the mobile station to the 
Aironet Access Point. Depending on the system in 
use, the telnet application may have logging and 
note taking capability. If so, enable these modes.
9.
Navigate through the Aironet Access Point menu to 
the link test option. See the appropriate Access 
Point Technical Reference Manual for more infor-
mation.
10. Set up the test options to accurately model the
system.
11. Set the test for continuous operation with a
1 second delay.
12. Begin traversing the area around the Aironet
Access Point to determine its coverage. If logging 
and notes are not possible with the telnet applica-
tion, maintain a manual log. 
The telnet session packets are interspersed with test 
packets which may have the effect of increasing the round 
trip time for some frames. The link test will show progress 
changes as the test is being conducted.
The first time delivery success rate for the packet may not 
be important for transaction based systems and can result 
in a slightly larger range. Using longer packets can provide 
some degree of safety margin in the range estimate.
NOTE: Roundtrip time will be effected by the telnet 
session maintenance.