Input connections, Warning, Phantom power for mic 5 & mic 6 – Bogen GOLD SEAL SERIES AMPLIFIERS GS-35 User Manual
Page 10: Remote volume control, Precedence connections
10
WARNING
Removal of the amplifier cover exposes internal components and presents an electrical shock hazard. For this
reason, do not perform any functions requiring removal of the cover of the amplifier unless you are qualified
to do so. Always disconnect AC power from the unit before attempting to remove the cover.
Phantom Power for MIC 5 & MIC 6
(Inside Unit)
A single internal jumper is provided to supply phantom power to both MIC 5 and MIC 6. The amplifier is shipped with
the jumper in the OFF position. Place Jumper across “ON” Pins to apply Phantom Power to both MIC 5 and MIC 6.
See the figure below for the location of the phantom power jumper.
Remote Volume Control
(Rear Panel; #10)
If remote volume control is desired, connect the Bogen acces-
sory GSRVC Remote Volume Control to the screw terminals
marked REMOTE MSTR. Wire length can be up to 1000 feet
using 22-gauge wire. Connections are not polarity sensitive.
Precedence Connections
(Rear Panel; #11)
Precedence connections allow any combination of inputs to
be completely muted with a contact closure. Closing a contact
across any of the precedence terminals and the PREC COM
1 terminal will mute that input. A customer-supplied normally-
open SPST switch, push-to-talk switch, microphone switch,
relay or telephone system contact can be used to provide the
closure.
Note: Activating the precedence control for AUX
inputs completely mutes the input signal. The
VAR MUTE control has no effect when muting
inputs using precedence control.
Phantom Power Jumper Location
for MIC 5 and MIC 6
Front
MIC 5 and MIC 6 input terminal strip
Input Connections