Installation, Air delivery— cfm (with filter) – Bryant PERFECT HEAT 331JAV User Manual

Page 4

background image

—4—

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

UNIT MUST BE INSTALLED IN ACCORDANCE

WITH INSTALLATION INSTRUCTIONS

Cancels: PDS 331J.60.3

© 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls., IN 46231

PRINTED IN U.S.A. Catalog No. 5233-103

10-99

AIR DELIVERY— CFM (With Filter)

A97620

UNIT

SIZE

BLOWER

MOTOR HP

SPEED

EXTERNAL STATIC PRESSURE (IN. WC)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

036060

1/3 PSC

High

Med-High

Med

Med-Low

Low

1435
1195
1030

900
705

1385
1165
1020

890
700

1320
1145
1010

875
690

1265
1105

985
855
675

1195
1070

955
835
655

1145
1015

915
795
625

1080

955
860
755
580

1000

885
790
690
525

048080

1/2 PSC

High

Med-High

Med

Med-Low

Low

1855
1595
1355
1170

880

1765
1570
1345
1170

865

1710
1530
1305
1140

855

1665
1485
1270
1110

830

1580
1410
1220
1075

805

1570
1355
1170
1025

755

1410
1280
1110

965
720

1310
1200
1025

890
655

060100

3/4 PSC

High

Med-High

Med

Med-Low

Low

2235
1995
1735
1510
1145

2185
1970
1735
1500
1140

2110
1915
1675
1485
1125

2030
1845
1625
1455
1115

1950
1765
1565
1400
1100

1835
1680
1480
1320
1085

1700
1545
1370
1230
1045

1540
1415
1265
1130

990

32

2

567

-10

1 R

E

V. E

(

L

IT

)

MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION

INSTALLATION

This unit is certified for downflow installation only. See Installation Manual for

important installation instructions.

This forced air furnace is equipped for

use with natural gas at altitudes 0 -
10,000 ft
(0-3,050m).

An accessory kit, supplied by the

manufacturer, shall be used to convert to
propane gas use or may be required for
some natural gas applications.

This furnace is for indoor installation in

a building constructed on site.

This furnace may be installed on

combustible flooring in alcove or closet at
minimum clearance from combustible
material.

This furnace may be used with a Type

B-1 Vent and may be vented in common
with other gas-fired appliances.

Clearance in inches.

BO

TTOM

##

1" #

0"

1"

1"

30"

MIN

S I

D E

F

R

O

N T

B

C

K

A

S E

R V

I

E

C

F R

ON

T

S I

E

U

F

R N

A C

E

#

Ø

TOP /

P

LEN

UM

D

1"

Ø

For installation on non-combustible

floors only. For installation on
combustible flooring only when
installed on special base, Part No.
KGASB0201ALL, Coil Assembly,
Part No. CD5 or CK5, or Coil
Casing, Part No. KCAKC.

For furnaces wider than 14.25

inches (362mm) may be 0 inches.

18 inches front clearance required

for alcove.

For single wall vent type 6 inches.

#

##

Vent Clearance to combustibles:

For Single Wall vents 6 inches (6 po).
For Type B-1 vent type 1 inch (1 po).

This furnace is approved for DOWNFLOW installations only.